罗氏COBAS HCV RNA定量一代和二代检测试剂对556例丙型肝炎患者HCV RNA定量检测结果的比较
DOI: 10.3969/j.issn.1001-5256.2014.12.020
Evaluation of two generations of HCV RNA quantitative kits: a comparative study of 556 cases of hepatitis C
-
摘要: 目的评估两代HCV核酸定量检测试剂的临床应用。方法收集南京市第二医院住院和门诊HCV感染者556例,采用罗氏COBAS HCV核酸定量一代和二代检测试剂检测其标本,其中HCV RNA阴性血浆93份;HCV RNA阳性血浆350份;血清血浆配对标本52份;干扰样本61份。将阳性血浆样本分为3组,低浓度(3次方及以下)61例、中浓度(4、5次方组)191例和高浓度89例(6次方及以上)。采用线性分析法,计算相关系数和回归方程,比较各组之间的关系。结果总体分析2种HCV RNA定量检测试剂的结果具有相关性(r=0.948,P<0.05)。低浓度组的线性回归方程y=0.9809x+0.1359,r2=0.8047,P>0.05;中浓度组的线性回归方程y=0.8130x+1.0727,r2=0.6956,P<0.01;高浓度组的线性回归方程y=0.6746x+1.8914,r2=0.3088,P<0.01。血清血浆有效对比检测结果的相关性良好(r2=0.9698,P<0.05),线性回归方程y=0.9368x+0.4469。结论两代HCV RNA定量检测试剂符合程度...Abstract: Objective To evaluate the clinical application of two generations of HCV nucleic acid quantitative kits: COBASAmpli Prep /COBASTaq Man HCV, v2. 0 and COBASAmpli Prep / COBASTaq Man HCV Test. Methods HCV RNA levels in 556 samples that were collected in our hospital were measured using the COBASAmpli Prep / COBASTaq Man HCV, v2. 0 and COBASAmpli Prep / COBASTaq Man HCV Test. The samples included 93 ones that were HCV RNA negative, 350 ones that were HCV RNA positive, 52 paired plasma and serum samples, and 61 ones with previous interferon therapy. HCV RNA-positive samples were divided into low-concentration group (≤103, 61 cases) , medium-concentration group (104-105, 191 cases) , and high-concentration group (≥106, 89 cases) . Comparison between groups was made by linear analysis to compute the correlation coefficient (r) and establish the regression equation. Results There was a significant correlation between the two generations of HCV nucleic acid quantitative kits (r = 0. 948, P < 0. 05) . The correlation between the two kits in the low-concentration group (y = 0. 9809 x + 0. 1359, r = 0. 8047, P > 0. 06) was higher than that in the medium-concentration group (y = 0. 8130 x + 1. 0727, r = 0. 6956, P < 0. 01) and that in the high-concentration group (y = 0. 6746 x + 1. 8914, r =0. 3088, P < 0. 01) . A high correlation between the two kits in paired serum and plasma samples was observed (y = 0. 9368 x + 0. 4469, r =0. 9698, P > 0. 05) . Conclusion The two generations of HCV RNA quantitative kits produce consistent results. A stronger correlation was shown in the low-concentration group, suggesting that the quantitative kits are more sensitive in detecting low level of HCV RNA in the clinical setting.
-
Key words:
- hepatitis C /
- RNA, viral /
- polymerase chain reaction /
- reagent kits, diagnostic
-
[1]LI MR, LIU HL, GUO JX, et al.Combination therapy with pegylated interferon alpha and ribavirin for the treatment of untreated patients and relapsed with chronic HCV infection[J].Int J Virol, 2013, 20 (6) :262-265. (in Chinese) 李敏然, 刘红磊, 郭军雪, 等.聚乙二醇干扰素联合利巴韦林治疗慢性丙型肝炎的疗效研究[J].国际病毒学杂志, 2013, 20 (6) :262-265. [2] European Association for the Study of the Liver.EASL Clinical Practice Guidelines:management of hepatitis C virus infection[J].J Hepatol, 2011, 55 (2) :245-264. [3]GHANY MG, NELSON DR, STRADER DB, et al.An update on treatment of genotype 1 chronic hepatitis C virus infection:2011practice guideline by the American Association for the Study of Liver Diseases[J].Hepatology, 2011, 54 (4) :1433-1444. [4]European Association for Study of Liver.EASL Clinical Practice Guidelines:management of hepatitis C virus infection[J].J Hepatol, 2014, 60 (2) :392-420. [5]CHEVALIEZ S, BOUVIER-ALIAS M, RODRIGUEZ C, et al.The Cobas Ampli Prep/Cobas Taq Man HCV test, version 2.0, real-time PCR assay accurately quantifies hepatitis C virus genotype 4RNA[J].J Clin Microbiol, 2013, 51 (4) :1078-1082. [6]ZITZER H, HEILEK G, TRUCHON K, et al.Second-generation Cobas Ampli Prep/Cobas Taq Man HCV quantitative test for viral load monitoring:a novel dual-probe assay design[J].J Clin Microbiol, 2013, 51 (2) :571-577. [7]FORNS X, COSTA J.HCV virological assessment[J].J Hepatol, 2006, 44 (Suppl 1) :s35-s39. [8]PAWLOTSKY JM, BOUVIER-ALIAS M, HEZODE C, et al.Standardization of hepatitis C virus RNA quantification[J].Hepatology, 2000, 32 (3) :654-659. [9]ALDANHA J, LELIE N, HEATH A.Establishment of the first international standard for nucleic acid amplification technology (NAT) assays for HCV RNA.WHO Collaborative Study Group[J].Vox Sang, 1999, 76 (3) :149-158. [10]SALDANHA J, HEATH A, ABERHAM C, et al.World Health Organization collaborative study to establish a replacement WHO international standard for hepatitis C virus RNA nucleic acid amplification technology assays[J].Vox Sang, 2005, 88 (3) :202-204. [11]NCCLS EP9-A2.Method comparison and bias estimation using patient samples;approved guideline-second edition[S].Wayne, PA:NCCLS, 2002. [12]YOU CG, PAN YY, GAO LN, et al.Quantitative assay of HBV-DNA repetition by Lightcycler system[J/CD].Chin J Clinicians:Electronic Edition, 2011, 5 (5) :1463-1465. (in Chinese) 尤崇革, 潘云燕, 郜莉娜, 等.Lightcycler系统定量检测HBVDNA的重复性[J/CD].中华临床医师杂志:电子版, 2011, 5 (5) :1463-1465.
本文二维码
计量
- 文章访问数: 234
- HTML全文浏览量: 15
- PDF下载量: 82
- 被引次数: 0