Role of dual-source CT low-dose whole liver perfusion imaging in evaluating liver blood perfusion after transjugular intrahepatic portosystemic shunt in cirrhotic patients with portal hypertension
-
摘要:
目的利用双源CT低剂量全肝灌注扫描技术观察肝硬化门静脉高压经颈静脉肝内门体分流术(TIPS)术前、术后肝实质血流动力学改变。方法收集2014年10月-2016年5月期间于兰州大学第一医院准备接受TIPS治疗的肝硬化门静脉高压患者52例,TIPS术前2 d及术后1周接受全肝灌注CT扫描,评价图像质量并利用后处理工作站观察灌注参数变化。计量资料组间比较采用配对t检验,各参数之间相关性分析采用Pearson直线相关分析法。结果肝脏动脉灌注量(HAP)由术前(19.85±9.48)ml/(min·100 ml)升高为(29.36±13.65)ml/(min·100 ml),肝动脉灌注指数(HPI)由术前(54.32±19.60)%升高为(64.11±11.19)%,差异均有统计学意义(t值分别为-6.161、-6.202,P值分别为0.003、0.029);而门静脉灌流量(PVP)由术前(19.75±10.60)ml/(min·100 ml)下降为(16.13±8.60)ml/(min·100 ml),总肝灌注量(TLP)由术前(36.14±16.61)ml/(min·100 ml)上升为(4...
-
关键词:
- 肝硬化 /
- 高血压,门静脉 /
- 体层摄影术,X线计算机 /
- 门体分流术,经颈静脉肝内
Abstract:Objective To investigate the role of dual-source CT low-dose whole liver perfusion imaging in evaluating the hemodynamic changes in liver parenchyma before and after transjugular intrahepatic portosystemic shunt( TIPS) in cirrhotic patients with portal hypertension. Methods A total of 52 cirrhosis patients with portal hypertension underwent whole liver perfusion CT scan 2 days before TIPS and at1 week after TIPS. The image quality was evaluated and a post-processing workstation was used to observe the changes in perfusion parameters. Paired t-test was applied for comparison between two groups,and pearson linear correlation was applied for correlation analysis. Results Hepatic arterial perfusion( HAP) increased from 19. 85 ml /( min·100 ml) ± 9. 48 ml /( min·100 ml) before TIPS to 29. 36 ml /( min·100 ml) ± 13. 65 ml/( min·100 ml) after TIPS( t =-6. 161,P = 0. 003),and the hepatic arterial perfusion index( HPI) increased from 54. 32% ± 19. 60% before TIPS to 64. 11% ± 11. 19% after TIPS( t =-6. 202,P = 0. 029). Portal vein perfusion( PVP)was reduced from 19. 75 ml /( min·100 ml) ± 10. 60 ml /( min·100 ml) before TIPS to 16. 13 ml /( min·100 ml) ± 8. 60 ml /( min·100ml) after TIPS,and total liver perfusion( TLP) increased from 36. 14 ml /( min ·100 ml) ± 16. 61 ml /( min ·100 ml) before TIPS to44. 12 ml /( min·100 ml) ± 14. 60 ml /( min·100 ml) after TIPS( both P > 0. 05). The mean effective radiation dose of whole liver perfusion scan was 16. 5 m Sv. PVP,TLP,and HPI were significantly correlated with the injection rate of contrast agent( r = 0. 992,P = 0. 001; r=-0. 903,P = 0. 036; r =-0. 899,P = 0. 038). HAP,PVP,and TLP were negatively correlated with the sample size( r =-0. 922,P =0. 026; r =-0. 943,P = 0. 016; r =-0. 998,P < 0. 001). TLP was positively correlated with the voltage of X-ray tube and scantimes( r =0. 896,P = 0. 039; r = 0. 907,P = 0. 033). Conclusion Dual-source CT low-dose whole liver perfusion can be used to observe the hemodynamic changes in cirrhotic patients with portal hypertension before and after TIPS and provide a reference for preoperative evaluation and therapeutic effect evaluation.
-
Key words:
- liver cirrhosis /
- hypertension /
- portal /
- tomograpy
-
[1]WU JJ,LI YC,SUN Y,et al.Change in liver perfusion parameters after transjugular intrahepatic portosystemic shunt and its clinical significance[J].J Chin Clin Med Imaging,2015,26(3):217-219.(in Chinese)吴晶晶,李迎春,孙勇,等.TIPS术后肝脏灌注指标的变化及临床意义[J].中国临床医学影像杂志,2015,26(3):217-219. [2]LANDRY G,GAUDREAULT M,van ELMPT W,et al.Improved dose calculation accuracy for low energy brachytherapy by optimizing dual energy CT imaging protocols for noise reduction using sinogram affirmed iterative reconstruction[J].Zeitschrift Fur Medizinische Physik,2016,26(1):75-87. [3]LI JP,CHEN W,HUANG YH,et al.Application of CT perfusion imaging on transjugular vein intrahepatic portal-systemic shunt[J].J Clin Radiol,2008,27(5):680-683.(in Chinese)李家平,陈伟,黄勇慧,等.CT灌注成像在经颈静脉肝内门体分流术中的应用[J].临床放射学杂志,2008,27(5):680-683.(in Chinese) [4]WEIDEKAMM C,CEJNA M,KRAMER L,et al.Effects of TIPS on liver perfusion measured by dynamic CT[J].AJR Am J Roentgenol,2005,184(2):505-510. [5]HUANG YH,CHEN W,LI JP,et al.Hemodynamic changes in liver measured by multi-imaging methods before and after transjugular intrabe patic portosystemic stent-shunt[J].Chin J Radiol,2007,41(12):1374-1378.(in Chinese)黄勇慧,陈伟,李家平,等.经颈静脉肝内门腔分流术后肝血流变化的综合影像评价[J].中华放射学杂志,2007,41(12):1374-1378. [6]GABA RC,KHIATANI VL,KNUTTINEN MG,et al.Comprehensive review of TIPS technical complications and how to avoid them[J].AJR Am J Roentgenol,2011,196(3):675-685. [7]MILES KA,HAYBALL M,DIXON AK.Colour perfusion imaging:a new application of computed tomography[J].Lancet,1991,337(8742):643-645. [8]WANG CH,WEI JP.Research advances in CT liver perfusion imaging[J].Jiangxi Med J,2015,50(4):369-371.(in Chinese)王川红,魏江平.肝脏CT灌注成像的研究进展[J].江西医药,2015,50(4):369-371. [9]JIN XL,YANG HF,DU Y,et al.CT perfusion imaging of liver and its application[J].Int J Dig Dis,2010,30(1):24-26.(in Chinese)靳秀丽,杨汉丰,杜勇,等.肝脏的CT灌注成像及其应用[J].国际消化病杂志,2010,30(1):24-26. [10]HUANG JH,SONG G,SHI L.Rationale of low-dose spiral CT and its clinical application[J].J Oncol,2016,22(4):316-321.(in Chinese)黄洁惠,宋歌,石磊.低剂量螺旋CT的原理及临床应用[J].肿瘤学杂志,2016,22(4):316-321. [11]SMITH AB,DILLON WP,GOULD R,et al.Radiation dose-reduction strategies for neuroradiology CT protocols[J].AJNR Am J Neuroradiol,2007,28(9):1628-1632. [12]HUANG YH,LI JP,XIE HB,et al.Evaluation of liver perfusion in cirrhosis patients with projects of maximum slope method on computed tomography[J].J Clin Radiol,2008,27(4):529-532.(in Chinese)黄勇慧,李家平,谢红波,等.CT最大斜率法定量测量肝硬化灌注指标的准确性分析及改良[J].临床放射学杂志,2008,27(4):529-532. [13]HO LM,YOSHIZUMI TT,HURWITZ LM,et al.Dual energy versus single energy MDCT:measurement of radiation dose using adult abdominal imaging protocols[J].Acad Radiol,2009,16(11):1400-1407. [14]WANG X,XUE HD,JIN ZY,et al.Quantitative hepatic CT perfusion measurement:comparison of Couinaud's hepatic segments with dual-source 128-slice CT[J].Eur J Radiol,2013,82(2):220-226. [15]LIAO HT,NIE SP.CT-associated radiographic contrast nephropathy[J].J Chin Practical Diagn Ther,2013,27(11):1041-1043.(in Chinese)缪黄泰,聂绍平.CT相关造影剂肾病[J].中华实用诊断与治疗杂志,2013,27(11):1041-1043. [16]STACUL F,van der MOLEN AJ,REIMER P,et al.Contrast induced nephropathy:updated ESUR Contrast Media Safety Committee guidelines[J].Eur Radiol,2011,21(12):2527-2541. [17]JIAO JY,XUE H.Research advances in the changes in hemodynamics and humor transmitter substances after transjugular intrahepatic portosystemic shunt[J].Shanxi Med J,2007,36(2):219-221.(in Chinese)焦婕英,薛挥.TIPS术后机体血流动力学及液递物质变化的研究进展[J].陕西医学杂志,2007,36(2):219-221.
计量
- 文章访问数: 2200
- HTML全文浏览量: 23
- PDF下载量: 473