中文English
ISSN 1001-5256 (Print)
ISSN 2097-3497 (Online)
CN 22-1108/R
Volume 35 Issue 5
May  2019
Turn off MathJax
Article Contents

Stent dysfunction after transjugular intrahepatic portosystemic shunt: Causes and countermeasures

DOI: 10.3969/j.issn.1001-5256.2019.05.023
Research funding:

 

  • Received Date: 2018-11-26
  • Published Date: 2019-05-20
  • Objective To investigate the causes of dysfunction of COOK bare stent, Wallgraft covered stent, and Fluency covered stent after transjugular intrahepatic portosystemic shunt ( TIPS) and related countermeasures. Methods The clinical data of 54 patients who were found to have stent dysfunction and underwent TIPS correction in our hospital from January 2011 to July 2017 were collected. Balloon dilatation, coaxial stent implantation, or parallel TIPS was selected based on angiography results and portal venous pressure to repair stent dysfunction. The Kruskal-Wallis H test was used to compare in-stent restenosis or occlusion time between the three types of stents, and the paired t-test was used to compare portal vein perfusion ( PVP) before and after correction. Radiological examination was performed to evaluate stent dysfunction, and the cause of in-stent restenosis or occlusion was analyzed. Results TIPS correction was successfully performed for all 54 patients. Stenosis was observed in the hepatic vein, the liver parenchyma, or the portal vein, and there was a high incidence rate within 6-24 months after surgery. The median time to stenosis or occlusion was 17. 0 months for COOK bare stent, 10. 0 months for Wallgraft covered stent, and 17. 0 months for Fluency covered stent. COOK bare stent and Fluency covered stent had a longer time to stenosis or occlusion than Wallgraft covered stent ( P = 0. 013 and 0. 023) , and there was no significant difference in the time to stenosis or occlusion between COOK bare stent and Fluency covered stent ( P = 0. 893) . As for the surgical procedure of TIPS correction, 4 patients underwent balloon dilatation, 39 underwent coaxial stent implantation, and 11 underwent parallel TIPS. There was a significant reduction in portal venous pressure after surgery ( 25. 6 ± 4. 8 cm H2O vs 34. 7 ± 6. 4 cm H2O, P < 0. 001) . Conclusion Wallgraft stent has a significantly shorter time to stent dysfunction after TIPS than COOK bare stent and Fluency covered stent, suggesting that Wallgraft stent is not suitable for the initial establishment of TIPS shunt. Correction procedures should be selected based on actual conditions to repair stent dysfunction and restore shunt patency.

     

  • loading
  • [1] Interventional Group, Chinese Society of Radiology, Chinese Medical Association. Expert consensus on transjugular intrahepatic portosystemic shunt[J]. J Clin Hepatol, 2017, 33 (7) :1218-1228. (in Chinese) 中华医学会放射学分会介入学组.经颈静脉肝内门体分流术专家共识[J].临床肝胆病杂志, 2017, 33 (7) :1218-1228.
    [2] TRIPATHI D, FERGUSON J, BARKELL H, et al. Improved clinical outcome with transjugular intrahepatic portosystemic stent-shunt utilizing polytetrafluoroethylene-covered stents[J]. Eur J Gastroenterol Hepatol, 2006, 18 (3) :225-232.
    [3] JOSE B, RIPOLL C, BANARES R, et al. Comparison of transjugular intrahepatic portosystemic shunt dysfunction in PTFE-covered stent-grafts versus bare stents[J]. Eur J Radiol, 2005, 55 (1) :120-124.
    [4] TRIPATHI D, FERGUSON J, BARKELL H, et al. Improved clinical outcome with transjugular intrahepatic portosystemic stent-shunt utilizing polytetrafluoroethylene-covered stents[J]. Eur J Gastroenterol Hepatol, 2006, 18 (3) :225-232.
    [5] BARRIO J, RAFAEL C, BANARE R, et al. Comparison of transjugular intrahepatic portosystemic shunt dysfunt dysfunction in PTFE-covered stent-grafts versus bare stents[J]. Eur J Radiol, 2005, 5 (1) :120-124.
    [6] QIN JP, JIANG MD, TANG W, et al. Clinical effects and complications of TIPS for portal hypertension due to cirrhosis:A single center[J]. World J Gastroenterol, 2013, 19 (44) :8085-8092.
    [7] QIN JP, TANG W, TANG SH, et al. Modified transjugular intrahepatic portoststemic shunt in the treatment of portal hypertension of liver cirrhosis[J]. Chin J Dig, 2014, 4 (13) :33-36. (in Chinese) 秦建平, 唐文, 汤善宏, 等.改良经颈静脉肝内门体静脉分流术治疗肝硬化门静脉高压症[J].中华消化杂志, 2014, 34 (1) :33-36.
    [8] LABERGE JM, FERRELL LD, RING EJ, et al. Histopathologic study of transjugular intrahepatic portosystemic shunts[J]. J Vasc Interv Radiol, 1991, 2 (4) :549-556.
    [9] LABERGE JM, FERRELL LD, RING EJ, et al. Histopathologic study of stenotic and occluded transjugular intrahepatic portosystemic shunts[J]. J Vasc Interv Radiol, 1993, 4 (6) :779-786.
    [10] ROSSI P, SALVATORI FM, FANELLI F, et al. Polytetrafluoroethylene-covered nitinol stent-graft for transjugular intrahepatic portosystemic shunt creation:3-year experience[J].Radiology, 2004, 231 (3) :820-830.
    [11] VIGNALI C, BARGELLINI IM, PASSALACQUA G, et al. TIPS with Expanded polytetrafluoroethylene-covered stent:Results of an Italian multicenter study[J]. AJR Am J Roentgenol, 2005, 185 (2) :472.
    [12] ANGELONI S, MERLI M, SALVATORI FM, et al. Polytetrafluoroethylene-covered stent grafts for TIPS procedure:1-year patency and clinical results[J]. Am J Gastroenterol, 2004, 99 (2) :280-285.
    [13] SAXON RR, MENDEL HJ, CORLESS CL, et al. Bile duct injury as a major cause of stenosis and occlusion in transjugular intrahepatic portosystemic shunts:Comparative histopathologic analysis in humans and swine[J]. J Vasc Interv Radiol, 1996, 7 (4) :487-497.
    [14] DUCOIN H, EL-KHOURY J, ROUSSEAU H, et al. Histopathologic analysis of transjugular intrahepatic portosystemic shunts[J]. Hepatology, 1997, 25 (5) :1064-1069.
    [15] SANYAL AJ, CONTOS MJ, YAGER D, et al. Development of pseudointima and stenosis after transjugular intrahepatic portasystemic shunts:Characterization of cell phenotype and function.[J]. Hepatology, 2010, 28 (1) :22-32.
    [16] CLARK TW, AGARWAL R, HASKAL ZJ, et al. The effect of initial shunt outflow position on patency of transjugular intrahepatic portosystemic shunts[J]. J Vasc Interv Radiol, 2004, 15 (2) :147-152.
    [17] MATTSSON EJ, KOHLER TR, VERGEL SM, et al. Increased blood flow induces regression of intimal hyperplasia[J]. Arterioscler Thromb Vasc Biol, 1997, 17 (10) :2245-2249.
    [18] BUREAU C, GARCIA-PAGAN JC, OTAL P, et al. Improved clinicaloutcome using polytetrafluoroethylene-coated stents for TIPS:Results of a randomized study[J]. Gastroenterology, 2004, 126:469-475.
    [19] MASSON S, MARDINI HA, ROSE JD, et al. Hepatic encephalopathyafter transjugular intrahepatic portosystemic shunt insertion:Adecade of experience[J]. QJM, 2008, 101 (6) :493-501.
    [20] HASKAL ZJ, RADHAKRISHNAN J. Transjugular intrahepatic portosystemicshunts in hemodialysis-dependent patients and patients withadvanced renal insufficiency:Safety, caution, and encephalopathy[J]. J Vasc Interv Radiol, 2008, 19 (4) :516-520.
    [21] LUO XF, NIE L, WANG Z, et al. Stent-grafts for the treatment of TIPS dysfunction:Fluency stent vs Wallgraft stent[J].World J Gastroenterol, 2013, 19 (30) :5000-5005.
    [22] CLARK TW, AGARWAL R, HASKAL ZJ, et al. The effect of initial shunt outflow position on patency of transjugular intrahepatic portosystemic shunts[J]. J Vasc Interv Radiol, 2004, 15 (2) :147-152.
    [23] KRAJINA A, LOJIK M, CHOVANEC V, et al. Stent-grafts in TIPS[J]. Abdom Imaging, 2004, 29 (1) :53-59.
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Article Metrics

    Article views (1679) PDF downloads(311) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return